METHOD DEVELOPMENT AND VALIDATION OFMETANEPHRINE AND NORMETANEPHRINE ON LIQUIDCHROMATOGRAPHY-TANDEM MASS SPECTROMETRY
DOI:
https://doi.org/10.53555/jptcp.v31i8.7531Keywords:
Liquid chromatography-mass spectrometry, metanephrine, normetanephrine, PheochromocytomaAbstract
Catecholamines and its metabolites play significant physiological roles in the human body.
Paraganglioma and pheochromocytoma are rare tumors of an adrenal region that affect the
catecholamines and their metabolites (metanephrine (MN) and normetanephrine (NMN))
concentration. Given the significance of these metabolites for diagnosing, managing, and
monitoring adrenal tumors, a method has been developed and validated using Liquid
Chromatography-Tandem Mass Spectrometry (LC-MS/MS). This method is specifically designed
for quantification of MN and NMN in urine. The objective of developing and validating this
analytical approach is to provide physicians with a reliable tool for assisting in the management of
adrenal tumors.
For sample extraction, 2-aminoethyl-diphenylborinate and ethyl acetate were used. The organic
layer was separated and dried under nitrogen at 50-60°C and reconstituted with mobile phase. The
chromatographic separation was done using the Agilent Eclipse C-18 column with two mobile
phases: (A) 5% Methanol in 0.1% Formic acid and (B) 100% Methanol in an isocratic flow. The run
times for MN and NMN were 1.259 and 1.268 min, respectively. The validated analytical measuring
range (AMR) was 7.8-1000 ng/mL with lower limits of quantification (LLOQ) 7.8 ng/mL for MN
and NMN, and the recovery was 95.11% to 105.6% for MN and 95.87% to 104.78% for NMN. The
method showed an excellent correlation (r2) of 0.997 for MN and 0.998 for NMN. The method was
found steady after inter-day and intra-day analysis with coefficients of variation (CV) <3% and
accuracy <6%. This validated method can be used for metabolite screening in clinical and research
settings.
References
Raber W, Kotal H, Marculescu R, Scheuba C, Niederle MB, Kautzky-Willer A et al. Measurements of plasma-free metanephrines by immunoassay versus urinary metanephrines and catecholamines by liquid chromatography with amperometric detection for the diagnosis of pheochromocytoma/paraganglioma. J Clin Med. 2020;9(10):3108. https://doi.org/10.3390/jcm9103108
Gabler J, Yuan C, Woroniecki W, Liu H, Wang SJJCST. A sensitive and interference-free liquid chromatography tandem mass spectrometry method for measuring metanephrines in plasma. J Chromatograph Separat Techniq. 2012;4(195):2. doi: 10.4172/2157-7064.1000195
Smy L, Kushnir MM, Frank ELJJoMS, lab AitC. A high sensitivity LC-MS/MS method for measurement of 3-methoxytyramine in plasma and associations between 3-methoxytyramine, metanephrines, and dopamine. J Mass Spectrom Adv Clin Lab. 2021;21:19-26. https://doi.org/10.1016/j.jmsacl.2021.08.001
Ellis AG, Zeglinski PT, Coleman KE, Whiting MJJCMS. Dilute, derivatise and shoot measurement of urinary free metanephrines and catecholamines as ethyl derivatives by LC-MSMS. Clin Mass Spectrom. 2017;4:34-41. https://doi.org/10.1016/j.clinms.2017.08.005
Li XS, Li S, Kellermann GJT. Pre-analytical and analytical validations and clinical applications of a miniaturized, simple and cost-effective solid phase extraction combined with LC-MS/MS for the simultaneous determination of catecholamines and metanephrines in spot urine samples. Talanta. 2016;159:238-47. https://doi.org/10.1016/j.talanta.2016.06.032
Woo HI, Yang JS, Oh HJ, Cho YY, Kim JH, Park H-D et al. A simple and rapid analytical method based on solid-phase extraction and liquid chromatography–tandem mass spectrometry for the simultaneous determination of free catecholamines and metanephrines in urine and its application to routine clinical analysis. Clin Biochem. 2016;49(7-8):573-9. https://doi.org/10.1016/j.clinbiochem.2016.01.010
Crockett DK, Frank EL, Roberts WLJCc. Rapid analysis of metanephrine and normetanephrine in urine by gas chromatography-mass spectrometry. Clin Chem. 2002;48(2):332-7. https://doi.org/10.1093/clinchem/48.2.332
Eisenhofer G, Peitzsch M, Kaden D, Langton K, Mangelis A, Pamporaki C et al. Reference intervals for LC-MS/MS measurements of plasma free, urinary free and urinary acid-hydrolyzed deconjugated normetanephrine, metanephrine and methoxytyramine. Clin Chim Acta. 2019;490:46-54. https://doi.org/10.1016/j.cca.2018.12.019
Kushnir MM, Rockwood AL, Nelson GJ, Yue B, Urry FMJCb. Assessing analytical specificity in quantitative analysis using tandem mass spectrometry. Clin Biochem. 2005;38(4):319-27. https://doi.org/10.1016/j.clinbiochem.2004.12.003
Lenders J, Eisenhofer G, Armando I, Keiser H, Goldstein D, Kopin IJCc. Determination of metanephrines in plasma by liquid chromatography with electrochemical detection. Clin Chem. 1993;39(1):97-103. https://doi.org/10.1093/clinchem/39.1.97
Clark ZD, Frank ELJJocB. Urinary metanephrines by liquid chromatography tandem mass spectrometry: Using multiple quantification methods to minimize interferences in a high throughput method. J Chromatogr B. 2011;879(31):3673-80. https://doi.org/10.1016/j.jchromb.2011.10.005
Taylor RL, Singh RJ. Validation of liquid chromatography–tandem mass spectrometry method for analysis of urinary conjugated metanephrine and normetanephrine for screening of pheochromocytoma. Clin Chem. 2002 Mar 1;48(3):533-9.https://doi.org/10.1093/clinchem/48.3.533
Willemsen JJ, Ross HA, Wolthers BG, Sweep CF, Kema IP. Evaluation of specific high-performance liquid-chromatographic determinations of urinary metanephrine and normetanephrine by comparison with isotope dilution mass spectrometry. Ann Clin Biochem. 2001 Nov 1;38(6):722-30.https://doi.org/10.1258/0004563011900984
Gabler J, Wang S. Quantification of metanephrine and normetanephrine in urine using liquid chromatography-tandem mass spectrometry. Clin App Mass Spectrome Biomol Anal: Methods and Protocols. 2016:149-57. https://doi.org/10.1007/978-1-4939-3182-8_17
Lee MS, Lee R, Park SH, Kwon SH, Park JY, Lee SW, Lee SM, Moon JE. Metanephrine negative pheochromocytoma: a rare case report of dopamine-secreting tumor in an adolescent neurofibromatosis type 1 patient. Ann Pediatr Endocrinol Metab. 2023 Dec;28(4):302. https://doi.org/10.6065%2Fapem.2244016.008
Woo HI, Yang JS, Oh HJ, Cho YY, Kim JH, Park HD, Lee SY. A simple and rapid analytical method based on solid-phase extraction and liquid chromatography–tandem mass spectrometry for the simultaneous determination of free catecholamines and metanephrines in urine and its application to routine clinical analysis. Clin Biochem. 2016 May 1;49(7-8):573-9.https://doi.org/10.1016/j.clinbiochem.2016.01.010
Weismann D, Peitzsch M, Raida A, Prejbisz A, Gosk M, Riester A, Willenberg HS, Klemm R, Manz G, Deutschbein T, Kroiss M. Measurements of plasma metanephrines by immunoassay vs liquid chromatography with tandem mass spectrometry for diagnosis of pheochromocytoma. Eur J Endocrinol. 2015 Mar;172(3):251-60. https://doi.org/10.1530/EJE-14-0730
FDA U. M10 Bioanalytical Method Validation and Study Sample Analysis–Guidance for Industry (2022).
Peris‐Vicente J, Esteve‐Romero J, Carda‐Broch S. Validation of analytical methods based on chromatographic techniques: An overview. AnalSep Sci. 2015:1757-808. https://doi.org/10.1002/9783527678129.assep064
Lenders JW, Eisenhofer G, Mannelli M, Pacak KJTL. Phaeochromocytoma. Lancet. 2005;366(9486):665-75. https://doi.org/10.1016/S0140-6736(05)67139-5
Därr R, Kuhn M, Bode C, Bornstein SR, Pacak K, Lenders JW et al. Accuracy of recommended sampling and assay methods for the determination of plasma-free and urinary fractionated metanephrines in the diagnosis of pheochromocytoma and paraganglioma: a systematic review. Endocrine. 2017;56:495-503. https://doi.org/10.1007/s12020-017-1300-y
Pappachan JM, Tun NN, Arunagirinathan G, Sodi R, Hanna FWJChr. Pheochromocytomas and hypertension. Curr Hypertens Rep. 2018;20:1-13. https://doi.org/10.1007/s11906-018-0804-z
Dikunets M, Dudko G, Glagovsky P, Mamedov I. Simultaneous Quantification of Plasma Catecholamines and Metanephrines by LC-MS/MS. J Braz Chem Soc. 2020;31:1467-74. https://doi.org/10.21577/0103-5053.20200033
Lefeuvre S, Bois-Maublanc J, Mongeois E, Policarpo V, Formaux L, Francia T, Billaud EM, Got L. Quantitation using HRMS: A new tool for rapid, specific and sensitive determination of catecholamines and deconjugated methanephrines metanephrines in urine. J Chromatogr B. 2021 Mar 1;1166:122391.https://doi.org/10.1016/j.jchromb.2020.122391
Downloads
Published
How to Cite
Issue
Section
License
Copyright (c) 2024 Journal of Population Therapeutics and Clinical Pharmacology

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
All articles published in JPTCP are licensed under Copyright Creative Commons Attribution-NonCommercial 4.0 International License.