New laboratory method extraction using ultrasound device by microbubble vortex phenomenon

Main Article Content

Ameer Mahdi Jaber
Mustafa Abdulkadhim Hussein

Keywords

ultrasonic device, Peristaltic pump, dithizone solution copper (II) chloride

Abstract

Innovative, sensitive and accurate method for liquid-liquid extraction using an ultrasonic device is presented in this work. A working system was created, consisting of two basic components: the ultrasonic device and the pump device, to pump or withdraw the organic layer A study of the key variables derived from the liquid-liquid system was carried out in the system containing Dithizone (1×10^-3 M) in (Chloroform) CHCl₃ solvent. and aqueous copper (II) chloride(CuC2.2H2O) (1×10^-6 M) solution to determine the degree to which they affect the extraction performance attained in this manner. The effect of initial sample copper concentration and ultrasonic time, temperature effect, pump speed, were studied, establishing the best conditions for a sample of (10 mL) aqueous solution of Cu (II) chloride, the optimum copper (II) concentration in the analyzed sample is (1×10^-6 M), the ultrasonic time for the device is (8 min), and the flowrate of the pump is (3mL/30sec) and a temperature (27ºC) and (pH=1). The extraction degree was optimum under these conditions (96±2%). The innovative ultrasonic extraction method's results were compared to previous studies, and they were found to be more efficient than the traditional methods of extraction using funnel separation and multiple extraction.

Abstract 88 | pdf Downloads 95

References

1. A. Baba, K. I. Ayinla, F. A. Adekola, M. K. Ghosh, P. C. Rout, and A. I. Ambo, “Extraction and purification of copper from a Nigerian chalcopyrite ore leach liquor by dithizone in kerosene,” Solvent Extr. Res. Dev. Japan, vol. 22, no. 2, pp. 135–146, 2015.
2. Alafara Abdullahi Baba,Ibrahim Ayinla,Malay Kumar Ghosh & Folahan Adekola"Extraction and Purification of Copper from a Nigerian Chalcopyrite Ore Leach Liquor by Dithizone in Kerosene", Japan magazine ,vol. 22, No. 2, May 2015.”
3. N. Mulligan, N. Davarpanah, M. Fukue, and T. Inoue, “Filtration of contaminated suspended solids for the treatment of surface water,” Chemosphere, vol. 74, no. 6, pp. 779–786, 2009.
4. Douglas A. Skoog, Donald M. West, F. James Holler, Stanley R. Crouch ’Fundamentals of Analytical Chemistry ’ ’, 9th Ed ,Crouch Publisher publishing house , 2013.”
5. E. N. Ali, S. A. Muyibi, H. M. Salleh, M. R. M. Salleh, and M. Alam, ‘Moringa oleifera seeds as natural coagulant for water treatment,’ in Thirteenth international Egyptian water technology conference, 2009, pp. 163–168.”
6. G. Z. Kyzas, A. C. Mitropoulos, and K. A. Matis, “From microbubbles to nanobubbles: effect on flotation,” Processes, vol. 9, no. 8, p. 1287, 2021.
7. J.-A. Hong, J.-S. Lee, and Y.-D. Jun, “Characterization of Extracted Dissolved Gas from Water,” J. Human-centric Sci. Technol. Innov, vol. 1, no. 2, pp. 23–30, 2021.
8. K. J. Laidler . ,"Chemical kinetics", 3th.Ed ,Harper publishing house ,New York ,1987.”
9. K. J. Laidler ‘Chemical kinetics’ Harper publishing house ,3th.Ed ,New York (1987) 111-113.”
10. P. L. Hibbard, “Estimation of Copper, Zinc, and Cobalt (with Nickel) in Soil Extracts Dithizone Methods Particularly Adapted to Examination of Soils,” Ind. Eng. Chem. Anal. Ed., vol. 10, no. 10, pp. 615–618, 1938.
11. Parmin, P., Suarayasa, K., & Wandira, B. A. (2020). Relationship between quality of service with patient loyality at general polyclinic of kamonji public health center. International Journal of Health & Medical Sciences, 3(1), 86-91.
12. Shannon, M. A.; Bohn, P. W.; Elimelech, M.; Georgiadis, J. G.; Marinas, B. J.; Mayes, A. M. Science and technology for water purification in the coming decades. Nature 2008, 452, 301−310.”
13. Sholl, D. S.; Lively, R. P. Seven chemical separations to change the world. Nature 2016, 532, 435−437.”
14. Emad. Mustafa Abdulkadhim Hussein “ Novel laboratory extraction method using magnetically micro bubble stream”, year 2022.